Humboldt Logo

Comparison of PV Module Performance Before and After 11-Years of Field Exposure

Show full item record

Title: Comparison of PV Module Performance Before and After 11-Years of Field Exposure
Author: Reis, Antonio M.; Coleman, Nathaniel T.; Marshall, Marc W.; Lehman, Peter A.; Chamberlin, Charles E.
Abstract: In 1990 the Schatz Energy Research Center (SERC) installed a PV array comprised of 192 ARCO M-75 modules. Prior to installation, Zoellick [1] carefully measured module performance and reported average peak power at normal operating cell temperature (NOCT) to be 39.88 W, which was 14.1% lower than the 46.4 W nameplate rating. For the past 11 years the array has been exposed to and employed in a cool, marine environment. Of the original 192 modules, 191 were recently tested in order to re-evaluate their performance. This paper describes the equipment, conditions, and procedure used in retesting the modules, and reports module performance results. Notable results are that average module short circuit current and maximum power production at NOCT have decreased by 6.38% and 4.39%, respectively.
Description: Presented at the 29th Institute of Electrical and Electronics Engineers (IEEE) Photovoltaic Specialists Conference, New Orleans, 2002
URI: http://hdl.handle.net/2148/44
Date: May 2002

Files in this item

Files Size Format View
PV Performance 2002IEEE.pdf 235.8Kb PDF Thumbnail

This item appears in the following Collection(s)

Show full item record

Search DSpace


Advanced Search

Browse

My Account

Statistics